1Pathology and Physiology Research Branch and 2Toxicology and Molecular Biology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), and 3Physiology and Pharmacology, West Virginia University, Morgantown, West Virginia; 4Lockheed Martin, Engineering Directorate, Materials and Processes Branch, and 5Nanotube Team, GB Tech, National Aeronautics and Space Administration Johnson Space Center, Houston, Texas; 6Monitoring Research and Statistical Activity, Division of Applied Research and Technology, NIOSH, Cincinnati, Ohio; 7Woodrow Wilson International Center for Scholars, Washington, District of Columbia; and 8Department of Environmental and Occupational Health, University of Pittsburgh, Pittsburgh, Pennsylvania
Submitted 23 April 2008 ; accepted in final form 18 July 2008
| ABSTRACT |
|---|
|
|
|---|
nanoparticles; lung disease
Several studies have demonstrated the toxicity of SWCNT to different types of cells in vitro (7, 19, 29). However, studies of in vivo effects of SWCNT are still scarce (28, 47, 55). At the time of writing, only a few published reports demonstrate the pulmonary toxicity of SWCNT (28, 32, 47, 55). Our previous work (47) documented an unusual inflammatory response to SWCNT delivered to the lung via pharyngeal aspiration characterized by a brisk acute phase inflammatory response followed by an early onset of lung fibrosis. Inflammation and pulmonary fibrosis have been associated with an increased risk for lung cancer (20) thus justifying assessments of genotoxic events possibly accompanying SWCNT exposure.
As pharyngeal aspiration delivers SWCNT as a bolus to the lung airways, this pulmonary response could potentially be caused by the high single dose of carbon nanotubes. Recent reviews have emphasized the lack of definitive inhalation studies that would avoid the potential for artifactual effects of large mats and agglomerates formed during instillation exposure procedures (10). Therefore, we developed an inhalation protocol to evaluate SWCNT effects on the lung. Because of the high propensity of hydrophobic SWCNT to agglomerate (3, 4), preparation of an adequate aerosol dispersion suitable for an inhalation protocol is immensely difficult. By applying a new technique to aerosolize SWCNT (2), we were able to obtain stable and uniform SWCNT dispersions suitable for the inhalation experiments. Here, we present the results of a study in which inhalation of nonpurified SWCNT (with an iron content of 17.7% wt) was compared with pharyngeal aspiration of various doses of the same SWCNT. We report that the inhalation route was more effective in causing inflammatory response, oxidative stress, collagen deposition, and fibrosis as well as mutations of K-ras gene locus in the lung of C57BL/6 mice compared with aspiration of a similar dose of SWCNT.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Experimental design. Experimental protocols for the present studies included inhalation and pharyngeal aspiration exposures of C57BL/6 mice to SWCNT. Animals were exposed in a whole body inhalation exposure chambers with individual steel mesh compartments for 4 consecutive days, 5 h/day. Aerosolized SWCNT were sampled from the breathing zone within each chamber for characterization during exposure. Mice from the control group were exposed to filtered air. After the last exposure, animals were removed from the chambers and euthanized 1, 7, and 28 days postinhalation. A suspension of SWCNT (0, 5, 10, and 20 µg per mouse) was used for single pharyngeal aspiration to additional groups of C57BL/6 mice, whereas the corresponding control mice were administered sterile Ca2+ + Mg2+-free PBS vehicle. Dose-dependent inflammatory response and pulmonary toxicity were evaluated, and the concentration of 10 µg per mouse of SWCNT was chosen for time course study. Mice were euthanized on days 1, 7, and 28 following the exposure. All experiments were repeated three times. Inflammation was evaluated by total cell counts, cell differentials, and accumulation of cytokines in the bronchoalveolar lavage (BAL) fluid. Pulmonary toxicity was assessed by elevation of lactate dehydrogenase (LDH) level in acellular BAL fluid. Fibrogenic responses to exposed materials were assessed by morphometric measurements and collagen deposition. Respiratory changes after SWCNT exposures were assessed by measurement of breathing patterns using whole body plethysmography (47).
Particles. SWCNT were purchased from Carbon Nanotechnology (CNI, Houston, TX). The nanotubes were manufactured using the high-pressure CO disproportionation process (HiPco) and were used in the inhalation and pharyngeal aspiration studies as produced; i.e., without being purified or otherwise treated after the initial production process. They were supplied as a very low density dry powder. The supplied SWCNT contained nanometer-scale Fe catalyst particles inherent in the HiPco process. The amount of metallic impurities was analyzed using nitric acid dissolution and inductively coupled plasma-atomic emission spectrometry (ICP-AES) performed according to the NMAM method 7300 for trace metals (NIOSH Manual of Analytical Methods, 2005). Analysis indicates that these SWCNT contained elemental carbon (82% wt), Fe (17.7%). Trace elements present included Cu (0.16%), Cr (0.049%), and Ni (0.046%). Raman spectroscopy, near-infrared spectroscopy, and thermo-gravimetric analysis (TGA) were used for purity assessment of HiPco SWCNT. The spectra of SWCNT sample revealed distinct peaks at Raman shift of 1,586–1,591 cm–1, corresponding to the characteristic G of SWCNT as well as D and G1 bands typically found in SWCNT spectra. The diameter of SWCNT measured by transmission electron microscopy (TEM) was 0.8–1.2 nm. The length of SWCNT was 100–1,000 nm measured by Carbon Nanotechnology using atomic force microscopy. The surface area of SWCNT measured by the nitrogen absorption-desorption technique (Brunauer-Emmett-Teller method, BET) was 508 m2/g. For pharyngeal aspiration, the suspension of SWCNT (0.7% PBS) was ultrasonicated (30 s x 3 cycles) using a Vibra-Cell High Intensity Ultrasonic Liquid Processor VCX 130 (Sonics & Materials, Newtown, CT) to improve dispersion of the particles before animal dosing.
Generation of an aerosol of SWCNT.
The generation system used to deliver respirable SWCNT structures (5 mg/m3) at a flow rate of 10 l/min to 2 animal exposure chambers each containing 12 mice as previously described (2). Briefly, aerosols containing SWCNT particles were generated using an aerosol dispersion system containing a powder feeder and a knife mill. The acoustically fluidized powder feeder, designed specifically for delivering the low-density material, allowed relatively constant feed rates over a period of
6 h. Because the material tends to form clumps and is difficult to handle, a static discharger containing 210Po strips was used to reduce the electrical charges on the particles to prevent agglomerate formation due to contact charging. In addition, a knife mill was set up to provide high shear forces to tear apart these agglomerates once they were formed. Before entering the inhalation chamber, the aerosol was passed through a settling chamber, followed by an air cyclone (GK 2.69; BGI, Waltham, MA) to remove the coarse portion of the particles from the aerosol by gravitational settling and centrifugal force. The cyclone had a 50% cutoff size of 4-µm aerodynamic diameter. The feed rate, mill speed, and air flow rate were adjusted to allow a target mass concentration of 5.0 mg/m3 in the chamber, 5 h/day for 4 days. The mean flow rate through each animal chamber was 5 l/min.
Mass concentration. SWCNT concentration within the exposure chambers was monitored in real-time by a DataRAM (Thermo Fisher Scientific, Waltham, MA). Gravimetric samples were also taken every 30 min at 2 sites within each exposure chamber using 25-mm polyvinyl chloride (PVC) filters at a flow rate of 1 l/min.
Particle size distribution. Particle size distribution was determined by using a Micro-Orifice Uniform Deposit Impactor (MOUDI, model 110; MSP, Shoreview, MN). The flow rate of the impactor was adjusted to 30 l/min to provide the size-classified samples with the known cutoff sizes of 18-, 10-, 5.6-, 3.2-, 1.8-, 1.0-, 0.56-, 0.32-, 0.18-, 0.10-, and 0.056-µm aerodynamic diameter, respectively. PVC filters were used as the collection substrates. Oleic acid was applied to the filters (oil-soaked filters) on alternate stages to avoid the potential particle bounce and reentrainment. Separate MOUDI runs with each stage oil-soaked were analyzed for iron content by ICP-AES according to NMAM method 7300 to determine mass mode aerodynamic diameter, assuming that iron was uniformly distributed throughout the SWCNT aerosol.
Particle morphology. Particle morphology was investigated from the size-classified samples using MOUDI. Although oleic acid was required to avoid particle bounce on the collection substrate, there is a concern that the presence of oleic acid on the substrate would interfere with microscopic observations of particles. With this concern, two types of substrates were prepared, the oil-soaked PVC filters (to prevent bounce) (Pall, Ann Arbor, MI) and the polycarbonate filters (to collect SWCNT samples) (Whatman, West Chester, PA) without any oleic acid coating. For each run, these two different substrates were placed on alternate MOUDI stages so that reliable samples (not oil-soaked) without particle loss from upper stages were obtained. By altering the stages for PVC and polycarbonate filters, a complete set of 11 samples were obtained in two runs. The mass concentration in the chamber was maintained constant during these two runs. The sample filters (polycarbonate) were prepared by applying a thin coating of Au/Pd layer for scanning electron microscopy (SEM) and attaching a 3-mm carbon-coated microscope grid at the center of the filter for TEM. This procedure was adopted because it has been successfully used in our laboratory for collecting other ultrafine particles, such as welding fume and ultrafine titanium dioxide particles.
Electron microscopy. The polycarbonate filters containing the samples of SWCNT particles were cut into equal sections and mounted onto aluminum stubs with silver paste. The deposited particles were viewed using a SEM (model 6400; JEOL, Tokyo, Japan) and also analyzed using energy dispersive X-ray analysis (SEM-EDS; Princeton Gamma Tech, Rocky Hill, NJ) at an electron beam voltage of 20 kV. Samples collected for TEM analysis were analyzed using a JEOL 1220 transmission electron microscope operating at 80 kV.
Particulate instillation.
Mouse pharyngeal aspiration was used for particulate administration (43). Briefly, after anesthetization with a mixture of ketamine and xylazine (62.5 and 2.5 mg/kg subcutaneous in the abdominal area), a suspension (
50 µl) of SWCNT prepared in PBS (5, 10, and 20 µg per mouse) was placed posterior on the throat and the tongue, which was held until the suspension was aspirated into the lungs. Control mice were administered sterile Ca2+ + Mg2+-free PBS vehicle. The mice revived unassisted after approximately 30 to 40 min. All mice in SWCNT and PBS groups survived this exposure procedure. This technique provided good distribution of particles widely disseminated in a peribronchiolar pattern within the alveolar region as was detected by histopathology. Animals treated with the particulates or PBS recovered easily after anesthesia with no behavioral or negative health outcomes. Mice were euthanized on days 1, 7, and 28 following the exposures.
Obtaining BAL from mice. Mice were euthanized with intraperitoneal injection of sodium pentobarbital (>100 mg/kg) and exsanguinated. The trachea was cannulated with a blunted 22-gauge needle, and BAL was performed using cold sterile PBS at a volume of 0.9 ml for first lavage (kept separate) and 1.0 ml for subsequent lavages. Approximately 5 ml of BAL fluid per mouse was collected in sterile centrifuge tubes. Pooled BAL cells for each individual mouse were washed in PBS by alternate centrifugation (800 g, 10 min, 4°C) and resuspension. Cell-free first fraction BAL aliquots were stored at 4°C for LDH assays, and the remainder was frozen at –80°C until processed.
BAL cell counting and differentials. The degree of inflammatory response was estimated by quantitating total cells, macrophages, and polymorphonuclear leukocytes (PMNs) recovered by BAL. Cell counts were performed using an electronic cell counter equipped with a cell-sizing attachment (Coulter Multisizer II with a 256C channelizer; Coulter Electronics, Hialeah, FL). Alveolar macrophages (AM) and PMNs were identified by their characteristic cell shape in cytospin preparations stained with Diff-Quick (Fisher Scientific, Pittsburgh, PA), and differential counts of BAL cells was carried out. Three hundred cells per slide were counted.
Lung lavage fluid cytokine analysis.
Levels of cytokines were assayed in the acellular BAL fluid following SWCNT inhalation or aspiration exposures. The concentrations of TNF-
and IL-6 (sensitivity of assay is 5–7.3 pg/ml) were determined using the BD Cytometric Bead Array Mouse Inflammation Kit (BD Biosciences, San Diego, CA). The concentrations of active transforming growth factor-β1 (TGF-β1) (sensitivity of assay is <15.6 pg/ml) was determined using an ELISA kit (BioSource International, Camarillo, CA).
Total protein and LDH activity in the BAL fluid. Measurement of total protein in the BAL fluid was performed by a modified Bradford assay according to the manufacturer's instructions (Bio-Rad, Hercules, CA) with BSA as a standard. The activity of LDH was assayed spectrophotometrically by monitoring the reduction of nicotinamide adenine dinucleotide at 340 nm in the presence of lactate using Lactate Dehydrogenase Reagent Set (Pointe Scientific, Lincoln Park, MI).
Lung preparation for microscopic evaluation. Preservation of the lung was achieved by vascular perfusion of a glutaraldehyde (2%), formaldehyde (1%), and tannic acid (1%) fixative with sucrose as an osmotic agent (35). This method of fixation was chosen to prevent possible disturbances of the air space distribution of deposited materials and maintaining physiological inflation levels comparable to that of the end-expiratory volume. This was performed using protocols previously employed to study pulmonary effects of SWCNT (47). Briefly, animals were deeply anesthetized with an overdose of sodium pentobarbital, the trachea was cannulated, and laparotomy was performed. Mice were then euthanized by exsanguination. The pulmonary artery was cannulated via the ventricle, and an outflow cannula was inserted into the left atrium. In quick succession, the tracheal cannula was connected to a 5 cmH2O pressure source, and clearing solution (saline with 100 U/ml heparin, 350 mosM sucrose) was perfused to clear blood from the lungs. The perfusate was then switched to the fixative. Fixed lung volume was measured by water displacement (49). Coronal sections were cut from the lungs. The lungs were embedded in paraffin and sectioned at a thickness of 5 µm with an HM 320 rotary microtome (Carl Zeiss, Thornwood, NY). Lung sections for histopathological evaluation were stained with hematoxylin and eosin and examined by a board certified veterinary pathologist for morphological alterations.
Sirius red staining. The distributions of type I and III collagen in the lung tissue were determined by morphometric evaluation of the Sirius red-stained sections (47). Briefly, paraffin lung sections (5-µm thick) were deparaffinized and dehydrated. To identify collagen fibers under the microscope, the sections were stained with F3BA/picric acid for 1–2 h, washed with 0.01 N HCl for 1 min, and counterstained with Mayer's hematoxylin for 2 min. The slides were then dehydrated and mounted with coverslip (23). Type I and III collagen stained by Sirius red was visualized, and six randomly selected areas were scored under polarized microscopy using image analysis. With this morphometric method, the average thickness of Sirius red-positive connective tissues in the alveolar wall was quantitatively measured. Volume and surface density were measured using standard morphometric analyses of points and intercept counting (54). Average thickness of the Sirius red-positive connective tissues of the alveolar wall was computed from two times the ratio of volume density of points to the surface density of the alveolar wall.
Field emission SEM examination.
For SEM, lung slices
1-µm thick were taken from the fixative-preserved lungs, dehydrated in a graded series of alcohol, critical point-dried, and then carbon coated. After carbon coating, the specimens were examined with a field emission SEM (FESEM; model S-4800; Hitachi) operated at between 5 and 20 kV.
Lung collagen measurements. Total lung collagen content was determined by quantifying total soluble collagen using the Sircol Collagen Assay Kit (Accurate Chemical and Scientific, Westbury, NY). Briefly, whole lungs were homogenized in 0.7 ml of 0.5 M acetic acid containing pepsin (Accurate Chemical and Scientific) with 1:10 ratio of pepsin to tissue wet weight. Each sample was stirred vigorously for 24 h at 4°C and centrifuged, and 200 µl of supernatant was assayed according to the manufacturer's instructions.
Preparation of lung homogenates. The whole mouse lungs were separated from other tissues and weighed before being homogenized with a Tissue-Tearor (model 985-370; Biospec Products, Racine, WI) in PBS (pH 7.4) for 2 min. The homogenate suspension was frozen at –80°C until processed.
HPLC assay of malondialdehyde. Accumulation of lipid peroxidation products was assessed by accumulation of malondialdehyde (MDA). MDA was analyzed by HPLC using a procedure described by Young and Trimble (56). Briefly, MDA was analyzed in lung homogenates following a reaction with thiobarbituric acid and phosphoric acid. A Waters HPLC system with a 717 Autosampler, a Waters Nova-Pak C18 column (5 µm, 150 x 3.9 mm), a Waters 600 controller pump, and a 474 fluorescence detector was used to measure MDA in samples. The wavelengths employed in the assay were 532 nm (excitation) and 553 nm (emission). Eluent was 25 mM phosphate buffer:CH3OH (1:1 vol/vol) at pH 6.5, and the flow rate was 0.8 ml/min. Under these conditions, the retention time for MDA was 6.5 min. The data acquired was exported from the Waters 474 detector and analyzed using Millennium 2000 software (Waters, Milford, MA).
Fluorescence assay for low molecular weight thiols. Low molecular weight thiol concentration in lung homogenates was determined using ThioGlo-1, a maleimide reagent, which produces a highly fluorescent adduct on its reaction with SH- groups (46). Low molecular weight thiol content was estimated by an immediate fluorescence response registered on addition of ThioGlo-1 to the lung homogenate. A CytoFluor multiwell plate reader Series 4000 (Applied Biosystems, Foster City, CA) was employed for the assay of fluorescence using excitation at 360/40 nm and emission at 530/25 nm with a gain of 50. The data obtained were exported and analyzed using CytoFluor Software (Applied Biosystems).
Quantitative measurement of total antioxidant status in the lung homogenates. Lung total antioxidant status was determined using the NWLSS Antioxidant Reductive Capacity Assay (Northwest Life Science Specialties, Vancouver, WA). Briefly, the test is based on the ability of antioxidants in the lung homogenate to reduce Cu2+ to Cu+, which reacts with bathocuproine to form a complex with maximal absorbance at 490 nm. Absorbance was measured before and after addition of bathocuproine. A standard curve was generated using uric acid.
Measurement of protein carbonyls in the lung homogenates. The quantity of oxidatively modified proteins assessed by measurement of protein carbonyls in lung homogenates was determined using the Biocell PC ELISA kit (Northwest Life Science Specialties). Sensitivity of assay is <0.1 nmol/mg protein.
Measurement of pulmonary function. Spontaneous breathing patterns were monitored using whole body plethysmography. Breathing patterns were monitored 24 h before SWCNT exposure (baseline) and then 1, 7, and 28 days following inhalation to detect treatment-related changes. Mice were acclimated to the plethysmograph for 10 min followed by 30 min of acquisition of spontaneous breathing data. Expiratory and inspiratory time, frequency, and relaxation time were calculated from the raw waveforms using BioSystem XA software version 2.0.248 (Buxco Electronics, Wilmington, NC) and expressed as percentage of control air-exposed mice.
K-ras mutation analysis. For mutation analysis, three successive lung sections were prepared from each mouse lung tissue paraffin-embedded block, combined, and treated with xylene/ethanol to eliminate the paraffin. DNA was extracted from each sample using the protocol combining proteinase digestion and phenol/chloroform extraction. DNA was recovered by ethanol precipitation and resuspension in distilled water and kept at –20°C until analyzed. A sensitive K-ras mutation detection method was used to combine nested PCR, mutant allele enrichment by BanI restriction enzyme digestion, and denaturing gradient gel electrophoresis (DGGE) to separate mutant alleles from wild-type alleles as previously described by Stabile et al. (50). Each mutant allele was isolated from the gel and further characterized by automated sequencing to determine the nature of the mutation.
Statistics. Treatment-related differences were evaluated using two-way ANOVA, followed by pairwise comparison using the Student-Newman-Keuls tests as appropriate. Statistical significance was considered at P < 0.05. Data are presented as means ± SE.
Statistical analysis for the mutation data was performed using a
2 test; the data were analyzed as counts (proportions) of mutations and no mutations among mice in a number of treatment/time groups. A P value
0.05, at least one of the proportions in that particular analysis, was considered statistically significant, although a valid
2 test requires expected counts in each cell of the analysis table to be
5.
| RESULTS |
|---|
|
|
|---|
4.2 µm determined by measuring the iron content of filters from various stages of a MOUDI cascade impactor (Fig. 1); the distribution was skewed to smaller particle sizes.
|
![]() |
5 µg.
Particle morphology.
SWCNT particles were collected on polycarbonate filters (for SEM) and microscope grids (for TEM) placed on different stages of MOUDI. Representative SEM and TEM images of SWCNT particles are shown in Fig. 2, A and B, respectively. Particles with different morphologies shown on the micrographs indicate that, even though their shapes and structures were different, they had similar aerodynamic behavior and thus were collected on the same MOUDI stage. Results from a series of SEM and TEM micrographs both indicate that there was a distinctive trend of decreasing particle size for particles collected on a lower stage of the MOUDI. This demonstrates that the strategy of using stages with and without oil-soaked filters alternately worked well for collecting SWCNT particles without the phenomena of particle bounce or reentrainment. By counting the images of the particles on the micrographs, the stage with the cutoff of 0.18 µm had the highest counts, indicating that the count mode aerodynamic diameter was
240 nm. This demonstrates that the aerosol produced by our generator contained a high number of nano-sized SWCNT structures. The SEM-EDS analysis (Fig. 2C) indicates that the particles were composed of mostly carbon with a fair amount of iron (Au and Pd were the sputter coating materials).
|
BAL cytology indicated a robust but transient accumulation of neutrophils after inhalation exposure to SWCNT with maximum on day 1 posttreatment with values returning toward control thereafter (Fig. 3A). An increased number of AM (Fig. 3B) and of total cells (Fig. 3C) reaching a maximum on day 7 postexposure was documented. Although inflammation returned toward control 28 days postinhalation, at this time point, PMNs, AM, and total cell numbers in BAL fluid remained significantly (7.1-, 1.4-, and 1.4-fold) elevated compared with the air control group, respectively. Dose-dependent increased levels of PMNs were found following pharyngeal aspiration of 5–20 µg per mouse SWCNT (Table 1). Time course of inflammatory cell accumulation in BAL fluid of mice exposed by pharyngeal aspiration to SWCNT (10 µg per mouse) revealed the highest response in PMN numbers on day 1 and AM on day 7 (Table 2). Notably, pharyngeal aspiration of 20-µg SWCNT resulted in a lower level of PMNs accumulation in BAL fluid 1 day postexposure compared with inhalation exposure with lung burden of 5 µg per mouse (Table 1 and Fig. 3A).
|
|
|
|
Histopathology. Morphological alterations in lungs from mice inhaling SWCNT were evaluated by a board-certified veterinary pathologist. The principal histopathological alterations in mice inhaling SWCNT were pulmonary inflammation, bronchiolar epithelial cell hypertrophy, and the presence of green-brown foreign material in the interstitium, intracellularly within individual macrophages or free of lung tissue and most frequently aggregated near bronchoalveolar junctions, often with associated AM (Fig. 5 and Table 3). Histopathological changes tended to be centered near the 1st generation alveolar ducts. Bronchiolar epithelial cell changes in the inhalation study were principally bronchiolar epithelial cell hypertrophy. Compared with the normal bronchiolar epithelium observed in control mice (Fig. 5A) 1-day postexposure group, hypertrophy was accompanied by hyperplasia. These foci of hypertrophy and hyperplasia were most frequently manifested as increased nuclear size, increased cytoplasmic volume, increased cytoplasmic basophilia, and occasional mitotic figures (Fig. 5, A and D). At 7 days postexposure, foci of bronchiolar epithelial cell hypertrophy were observed in all exposed mice, but hyperplasia was associated with hypertrophy in only one mouse. At 28 days postexposure, four of the five exposed mice had bronchiolar epithelial cell hypertrophy with one mouse having both hypertrophy and hyperplasia, one mouse having peribronchiolar bronchiolization accompanying bronchiolar epithelial cell hypertrophy, and two mice having bronchiolar epithelial cell hypertrophy without other bronchiolar alterations. At 1 day after inhalation, inflammation was classified as histiocytic or histiocytic and neutrophilic (Fig. 5B). Throughout the postexposure time course, macrophages were the principal inflammatory cells (Fig. 5). An atypical mitotic figure was observed in one mouse at 7 days postexposure, and material consistent with SWCNT nanoropes intertwined with the abnormal mitotic figure (Fig. 5C). This suggests the potential for SWCNT to interfere with the mitotic spindle. In addition, macrophages occasionally did not have nuclei. These anuclear macrophages often had increased cytoplasmic eosinophilia and were not observed in control mice or at 1 day post-SWCNT inhalation but were noted in four of five mice 7 days postexposure and in five of five mice at 28 days postexposure (Fig. 5D and Table 3). The anuclear macrophages suggested either abnormal mitoses or an apoptotic process involving karyolysis. By 28 days postexposure, foci of granulomatous inflammation were often well-organized (Fig. 5E) with fibrosis seen in sections stained with Masson's trichrome (Fig. 5F). Histopathological changes are summarized in Table 3. As demonstrated by histopathology and illustrated by FESEM examination of lung specimens (Fig. 6), inhalation exposure to SWCNT produced granulomatous inflammation in the alveolar region of the lungs. Following the exposure, the epithelioid macrophages develop an extensive system of fingerlike projections over the surface of the granulomas 28 days postexposure (Fig. 6).
|
|
|
and IL-6 were 4.4- and 7.9-fold higher compared with air control groups, respectively. Dose-dependent increased levels of TNF-
and IL-6 were found following pharyngeal aspiration of 5–20 µg per mouse SWCNT (Table 1). No significant difference in the levels of proinflammatory cytokines was found between aspiration of 10 µg of SWCNT and inhalation with lung burden of 5 µg. Significant elevation of TGF-β1 release was found in BAL fluid of C57BL/6 mice after SWCNT inhalation throughout the recovery time course (Fig. 7C). Maximal fibrogenic TGF-β1 release after SWCNT inhalation was observed on day 7 and was significantly greater than after aspiration of 10-µg SWCNT (Table 2).
|
|
|
|
|
|
|
| DISCUSSION |
|---|
|
|
|---|
Our previous studies established that aspiration of highly purified SWCNT (without significant admixtures of transition metals such as iron) indeed caused unusual inflammatory responses in the lung of exposed animals: a truncated but strong acute phase response followed by an early onset and progressive fibrotic response (47). This was accompanied by disturbed breathing pattern (47) and increased susceptibility to pulmonary infection (48). Some argue that pharyngeal aspiration, a single exposure to a bolus of SWCNT, is an artificial exposure and that the bolus exposure may contribute to the pulmonary response. Moreover, aspiration studies reported thus far have been relatively high-dose exposures, which may not be relevant to chronic lower dose exposures in occupational settings (26). Before the current study, there was "no definitive inhalation study available that would avoid the potential for artifactual effects due to large aggregates forming during instillation exposure procedures" (10). Inhalation of SWCNT more closely mimics occupational and environmental settings than aspiration in that exposures are to more dispersed SWCNT structures and bolus effects are avoided. Therefore, we were eager to explore the pulmonary effects of inhaled SWCNT.
Technically, aerosolization of SWCNT and the inhalation exposures are very difficult because of their hydrophobicity and tendency to agglomerate yielding large entangled structures, often "bird's nest"-like, micrometer-size structures (33). As a result of formation of large agglomerates in suspension, asphyxia has been reported in rats following intratracheal instillation of poorly dispersed SWCNT (55). To avoid these substantial complications, we have developed special protocols and devices for adequate aerosolization of SWCNT (2). This technique included removing clumps, suspending by acoustic fluidization, breaking apart large agglomerates, and passing through a static discharger, settling chamber, and a cyclone (4-µm cutoff) to deliver SWCNT at a flow rate of 10 l/min. Application of our aerosolization technology resulted in the ability to obtain stable SWCNT aerosols with a concentration of 5 mg/m3 with a count mode aerodynamic diameter of 240 nm.
Using the stable SWCNT aerosols, we were able to conduct inhalation studies to assess their pulmonary effects. The manufacturing of nanotube material relies on the use of transition metal catalysts. Redox active iron within carbonaceous particles may act as a catalyst of oxidative stress in biological settings. The major toxicity mechanisms induced by SWCNT include induction of inflammatory response and oxidative stress exacerbated by iron. Because inflammation provides a redox environment in which transition metals can fully realize their prooxidant potential, a combination of inflammatory response with catalytically competent metal-containing carbon nanotubes would synergistically enhance damage to cells and tissue. Therefore, in the current study, we chose to use nonpurified SWCNT containing up to 17.7% (weight) of iron for both inhalation and aspiration exposures. Assessment of nonpurified SWCNT employed in this study with purified SWCNT (0.2% of iron by weight) used in our previous study (47) shows that the higher content of iron was associated with enhancement of oxidative stress and some of the pulmonary responses. These include more pronounced decrease of content of low molecular weight thiols, elevated cell damage assessed by the release of LDH, and higher level of collagen deposition in the lung of animals exposed to SWCNT by aspiration.
Comparison of the inhalation protocols with previously reported results on aspiration showed that all unusual features of pulmonary response were retained or enhanced. That is, the short and strong acute inflammatory phase reaction was followed by a robust deposition of collagen leading to progressive fibrosis. Comparison of dose dependencies for aspiration exposures (5, 10, and 20 µg of SWCNT per mouse) with that for inhalation (deposited dose of 5 µg per mouse) showed that deposition of smaller SWCNT structures after inhalation resulted in cellular inflammation, LDH and protein release, and cytokine production two- to fourfold greater than those after aspiration exposure of larger SWCNT structures. Morphometric evaluation of Sirius red-stained lung sections revealed that SWCNT inhalation caused a fourfold increase in fibrosis compared with that seen after pharyngeal aspiration of SWCNT with collagen deposition in the peribronchial as well as interstitial areas. Overall, our results demonstrate that SWCNT inhalation exposure was much more potent than aspiration of a bolus dose of SWCNT. Interestingly, Mercer et al. (36) demonstrated a fourfold greater fibrotic potency after pharyngeal aspiration of a well-dispersed SWCNT compared with a less dispersed suspension. They associated this potency difference with a greater potential for smaller SWCNT structures to enter the alveolar walls and cause interstitial fibrosis. Thickening of alveolar walls has also been demonstrated in mice inhaling multiwalled carbon nanotubes (30).
Inflammation and resulting fibrosis have been considered as significant risk factors in pulmonary carcinogenesis (20). Among the mutated genes implicated in pulmonary tumorigenesis, K-ras oncogene is frequently found in lung tumors of mice exposed to chemicals (8, 45). It was therefore important to investigate whether this gene mutation occurred after SWCNT exposure. We detected the increased rate of SWCNT-induced mutations that took place very early after SWCNT inhalation (on days 1–7) and persisted through day 28. The effect was coincident with the time of maximal inflammatory response suggesting that inflammation and resultant oxidative injury may be a cause of mutagenicity. Given that oxidative burst and accompanying oxidative stress are known to be significant contributors to genotoxicity, it is tempting to speculate that there is a causative association between accumulation of K-ras mutations and oxidative stress triggered by SWCNT inhalation. The types of mutations consisted of G-to-A transition that changes the wild-type codon 12 of the K-ras gene from GGT (glycine) to either AGT (serine) or GAT (aspartate). This type of mutation has been reported previously in lung tumors from susceptible mice (8, 45). For instance, lung tumors in mice exposed to the lung carcinogen, NNK [4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone], showed a high proportion of this mutation that has been suggested to occur via the mutagenic lesions, including O6-methylguanine, induced by NNK metabolites (8). Interestingly, one of the mutations found in SWCNT-treated mice (at day 28 post-SWCNT inhalation) consisted of a double mutation occurring at codons 12 and 8 [GGT to GAT and GTG to ATG (valine to methionine), respectively]. The role of this double mutation is unknown and may be specific for SWCNT exposure.
Overall, these results are intriguing because K-ras mutations have been reported only in lung tumors from susceptible mice, such as the FVB/N mice, exposed to lung carcinogens (8, 45, 50). The K-ras gene is a member of the ras gene family consisting of the closely related H-, K-, and N-ras genes, which code for similar 21-kDa proteins (ras) that are involved in the signal transduction pathways. Activation of ras genes occurs with specific point mutations primarily at codon 12 and to a lesser extent at codons 13 and 61 and has been implicated in lung tumorigenesis (1, 22, 25). The significance of these low-fraction K-ras mutations in C57BL/6 mice is unknown. Several studies have shown an association between lung fibrosis and an increased risk of lung cancer (18, 20, 27). It was proposed that fibrosis might be involved in the carcinogenesis by the occurrence of atypical or dysplastic epithelial changes, which progressed to invasive malignancy (18). However, the involvement of K-ras mutations in fibrosis-associated lung cancer is not understood and merits further investigation. The detected mutations frequency of 62.5% (10/16) in mice after SWCNT inhalation is significantly higher than that in the untreated group of mice 26.7% (4/5). Further studies involving a bigger sample size may help in determining the usefulness of this gene mutation as a biomarker of exposure to SWCNT. Furthermore, the potential role in lung carcinogenesis requires further investigation by comparing C57BL/6 mice with other mouse strains susceptible to lung tumor formation.
Our results, which show that SWCNT inhalation induced unusual and robust inflammatory response and fibrosis, raise the question of the relevance of doses and conditions used in the current study to realistic human occupational exposures. Exposure to carbonaceous materials has been reported to cause pneumoconiosis in workers exposed to both natural and man-made graphite (37). Severe symptomatic cases with massive pulmonary fibrosis in the past were observed during carbon electrode production (45a). Mixed dust pneumoconiosis caused by long-term occupational exposure to graphite dust is a rare disease (9). Screening and clinical examination of 746 graphite workers revealed an elevated occurrence of upper respiratory tract infections, chronic bronchitis, and pneumonia (24). Hypertrophic laryngitis, papillomatous bronchitis, and angiofibroma of the larynx, considered to be precancerous lesions, have also been reported. However, recent reports emphasized that such exposures are likely to be associated with mixed dusts (45a).
Previously, we investigated the potential exposure levels of workers to SWCNT in a small-scale production setting (33). Under these conditions, the amount of material produced was very small (several grams), significant care was taken to reduce product loss during handling, and the observed airborne particle concentrations were low (with peak exposure of 53 µg/m3). Agitation of the material by vortexing generated higher levels of respirable SWCNT material. Thus, under large-scale manufacturing conditions, the potential for occurrence of occupational exposure may exist. In the current study, we observed that toxic outcomes of exposure of C57BL/6 mice to aerosolized respirable SWCNT (5 mg/m3, 5 h, 4 days) resulted in a calculated lung burden of 5 µg per mouse. This lung burden would be achieved by workers exposed for <1 yr at the peak airborne concentrations measured in an occupational setting based on the studies of Maynard et al. (33). Our results may be important for establishing a permissible exposure level (PEL) for SWCNT. The exposure concentration, which we used in our inhalation studies, is the same as the current PEL set by Occupational Safety and Health Administration for respirable synthetic graphite dust, i.e., the PEL currently applied for SWCNT. Based on the outcomes of our inhalation study, it could be inferred that if workers were subjected to long-term exposures to respirable SWCNT at current PEL for synthetic graphite, they would likely have increased risk for pulmonary changes. Our results may be also compared with regulatory permissible levels established for ambient microparticles such as Environmental Protection Agency standard for PM2.5, which is 65 µg/m3 24 h daily and 15 µg/m3 annual average (53).
Overall, our data suggest that outcomes of inhalation exposure to respirable SWCNT were very similar to those seen after pharyngeal exposure route leading to pulmonary toxicity. The chain of pathological events was realized through synergized interactions of inflammatory response and oxidative stress culminating in the development of multifocal granulomatous pneumonia, interstitial fibrosis, and mutagenesis. Because of exposure to smaller SWCNT structures by inhalation of a dry aerosol vs. aspiration of a particle suspension containing micrometer-size agglomerates, inhalation exposure was, in fact, more potent than aspiration of an equivalent mass of SWCNT.
| GRANTS |
|---|
|
|
|---|
| DISCLAIMER |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
L. Ma-Hock, S. Treumann, V. Strauss, S. Brill, F. Luizi, M. Mertler, K. Wiench, A. O. Gamer, B. van Ravenzwaay, and R. Landsiedel Inhalation Toxicity of Multiwall Carbon Nanotubes in Rats Exposed for 3 Months Toxicol. Sci., December 1, 2009; 112(2): 468 - 481. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. B. Warheit Long-term Inhalation Toxicity Studies with Multiwalled Carbon Nanotubes: Closing the Gaps or Initiating the Debate? Toxicol. Sci., December 1, 2009; 112(2): 273 - 275. [Full Text] [PDF] |
||||
![]() |
U. C. Nygaard, J. S. Hansen, M. Samuelsen, T. Alberg, C. D. Marioara, and M. Lovik Single-Walled and Multi-Walled Carbon Nanotubes Promote Allergic Immune Responses in Mice Toxicol. Sci., May 1, 2009; 109(1): 113 - 123. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |